Support Projectors BrightLink Series Epson BrightLink 685Wi+

How do I replace the lamp?

  • Before you replace the lamp, let the projector cool down for at least one hour so the lamp will not be hot.

    Warning: Let the lamp fully cool before replacing it to avoid injury.

    You can replace the lamp while the projector is mounted on the wall or ceiling.

    1. Turn off the projector and unplug the power cord.
    2. Allow the projector lamp to cool down for at least one hour.

      Warning: If the lamp is broken, glass fragments may be loose inside the lamp chamber. Be careful removing any broken glass to avoid injury. If the projector is mounted on the wall or ceiling, stand to the side in case the lamp is broken.

    3. Use the screwdriver included with the replacement lamp to loosen the screw securing the lamp cover.

    4. Slide off the lamp cover.

    5. Loosen the screws securing the lamp to the projector. The screws do not come all the way out.

    6. Lift up the lamp handle and gently pull the lamp out of the projector.

      Note: The lamp(s) in this product contain mercury. Please consult your state and local regulations regarding disposal or recycling. Do not put in the trash.

    7. Gently insert the new lamp into the projector along the guide rail. If it does not fit easily, make sure it is facing the right way. Press the handle down.

      Caution:
      Do not touch any glass on the lamp assembly to avoid premature lamp failure.



    8. Tighten the screws to secure the lamp.

    9. Replace the lamp cover and tighten the screw to secure it.

      Note: Be sure the lamp cover is securely installed or the lamp will not come on.

    Reset the lamp timer to zero to keep track of the new lamp’s usage.

    Related tasks
    Resetting the Lamp Timer
Published:  Sep 6, 2018 Was this helpful? Thank you for the feedback!
Was this helpful?
Please tell us why this was not helpful.